top of page

Facility Siting Studies & Modeling Solutions

Facility siting studies are advised as part of new projects (green or brown field) and modification of existing facilities (buildings, population and process changes, introduction of new chemicals or products). In cases where a facility has applicability to the OSHA PSM and/or EPA RMP standards, conducting baseline and revalidation facility siting studies are required by these regulatory authorities to assess the consequences of potential incidents such as fires, explosions, or toxic exposure on individuals both onsite and off. Evaluating the impact of these facility operational risks is vital when creating a comprehensive safety plan.

 

aeSolutions' facility siting and consequence modeling experts work hand in hand with your team to identify potential process hazards, accounting for your operation's specific siting protocols and goals. aeSolutions is an industry-trusted provider of risk-based and consequence-based facility siting studies in addition to gas dispersion modeling, gas sensor mapping, and gas detector placement.

Facility Siting Studies - aeSolutions - 1.webp
AES Logo-Registered Squared off.jpg

Why Partner With Us?

At aeSolutions, we believe one of the greatest influences on operational excellence is a comprehensive, sustainable risk management program that addresses both conformance and compliance. For over 25 years, aeSolutions has served as a multi-faceted safety solutions provider across a wide gamut of industries. When it comes to facility siting studies, we leave no stone unturned. aeSolutions' team of trained facilitators execute the hazard recognition and risk reduction process while our experienced modelers apply the appropriate methodology in line with API 752/753/756 in addition to industry best management practices.

 

​

In short, we provide results that enable effective allocation of resources to minimize facility siting risks by your site leadership team.​​

Trust Built On Experience

​

aeSolutions - 100+ Years of combined fac
Years of Combined Experience In Facility Siting Studies
aeSolutions - 300+ Facility Siting Studi
Facility Siting
Studies Completed
aeSolutions - 25+ Years of Experience_ed
Years Serving
the Industry
Ground level ventilation patterns - aeSolutions Facility Siting Studies.webp
Ammonia Indoor Concentration - aeSolutions Facility Siting Studies.webp
Air Velocity Outside around AHU.jpg
Facility Siting Studies - aeSolutions - Range Graphic 2.jpg
Facility Siting Studies - aeSolutions - Range Graphic 3.jpg
Facility Siting Studies - aeSolutions - Range Graphic 1.jpg
Facility Siting Study and Analysis Icon
Facility Siting Study & Analysis

Our Facility Siting Capabilities

Risk Based and Consequence Based Studies
Risk-Based & Consequence-Based Studies
Gas Dispersion Modeling Icon - aeSolutio
Gas Dispersion
Modeling
Gas Modeling Icon - aeSolutions_edited.png
Fire
Modeling
Computational Fluid Dynamics CFD Modelin
Computational Fluid Dynamics (CFD) Modeling
Gas Sensor Mapping Icon - aeSolutions_ed
Gas Sensor
Mapping
Gas Detector Placement Icon - aeSolution
Explosion Modeling Facility Siting Studi
Explosion
Modeling

In accordance to API 752, 753, 756 recommended practices and the Center for Chemical Process Safety (CCPS) Guidance.

The aeSolutions Six Step Approach

1 Icon - aeSolutions_edited.png

Identify chemicals of concern

2 Icon - aeSolutions_edited.png

Identify site-specific conditions

3 Icon - aeSolutions_edited.png

Identify potential hazard event scenarios from review of site data

4 Icon - aeSolutions_edited.png

Identify & classify occupied buildings

5 Icon - aeSolutions_edited.png

Perform the hazard and consequence analysis

6 Icon - aeSolutions_edited.png

Perform the risk management analysis

aeSolutions utilizes DNV-GL's PHAST to provide quantitative fire and toxic effect data for pool fires, vapor cloud fires, vapor cloud explosions, jet fires, and toxic vapor clouds. Results are illustrated on a site plot plan with hazard endpoint circles for radiant heat, toxic concentrations, and pressure/impulse waves. Additionally, aeSolutions may perform computational fluid dynamics (CFD) models for highly hazardous scenarios upon request.  

Industries Served

chemical icon 2_edited_edited_edited.png
Chemical
Mining Icon - aeSolutions_edited.png
Metals & Mining
renewables_edited_edited_edited.png
Renewable Energy
Hydrogen Icon - aeSolutions_edited_edite
Hydrogen
Agricultural Chemicals Icon - aeSolutions_edited.png
Agriculture
petrochemical icon 2.png
Petrochemical
specialty chemical_edited_edited.png
Specialty Chemical
alt energy 2_edited_edited_edited.png
Energy & Alternative Energy
Oil Pump Icon_edited.png
Oil & Gas
pahrma icon 2_edited.png
Pharmaceutical
utilities icon 2_edited_edited.png
Utilities
LNG Icon (Cropped)_edited.png
LNG

About Facility Siting Studies

A Facility Siting Analysis is intended to evaluate the potential hazards and consequences of uncontrolled releases of flammable and toxic substances; to assess their potential for injuring the occupants of fixed and temporary structures on or offsite; to identify existing safeguards; and to determine measures to reduce the risk posed by these potential events.​

​

Within the United States, facility siting is required as an element of Process Hazard Analysis (PHA) for sites covered by the Occupational Safety and Health Administration's (OSHA) Process Safety Management (PSM) Standards under 29 CFR 1910.119 (e)(3)(v). 

​

aeSolutions' Facility Siting Studies are conducted in accordance with methods listed in the American Petroleum Institute's (API) Recommended Practices 752, 753, and 756, and published guidance from the Center for Chemical Process Safety (CCPS). 

​

Facility Siting is a multi-faceted analysis of potential fire, explosion, and toxic hazards to personnel from releases of hazardous chemicals. These chemicals of concern include those that vaporize quickly, are highly toxic to personnel or the environment, have low flash points and boiling points, are highly reactive, and/or are present at temperatures, pressures, and/or in quantities significant enough to pose a hazard of concern. 

Facility Siting Studies - aeSolutions - 2.webp

Ready to Discuss Your Facility Siting Study?

Recent Posts
bottom of page